• expatriado@lemmy.world
    link
    fedilink
    arrow-up
    2
    ·
    2 months ago

    the path of least resistance for the current would be down one connected bolt, then around the top plate, and up the other battery connected bolt, never down the pole, so the ceiling/floor gets heated up, possibly burn

    note: those bolts must be supper long to go from ceiling to floor

    • tyler@programming.dev
      link
      fedilink
      arrow-up
      1
      arrow-down
      1
      ·
      2 months ago

      12v is hardly anything. This is not a joke, go put your hands on both terminals of a car battery. You won’t feel a thing.

      • expatriado@lemmy.world
        link
        fedilink
        arrow-up
        1
        ·
        edit-2
        2 months ago

        still can spin a big truck and/or turn on incandescent bulbs with temperatures in the thousands of degrees

        the internal resistance of lead-acid batteries is in the tens of mili-Ω, the circuit of 2 cables, 2 bolts and one plate/top of the pole would be in the low 100s mili-Ω. lets round up to 200mΩ, power = V•I = V^2/R = 12^2/0.2 = 720W, enough to heat up the top assembly of the pole, and smolder some wood